Regular Members

Zhong Ke Base International Medical Technology (Beijing) Co.,Ltd

Health & Medical

Product category
  • N/A
Search
 
Friends links
  • N/A
Supplier Homepage > Products > BASE850 Ventilator With Compressor
BASE850 Ventilator With Compressor
Click on the image to check the artwork
product: view count: 155BASE850 Ventilator With Compressor 
unit price: Negotiable
min amount:
amount:
period for delivery: Consignment Deadline days
Expiry date: Long Effective
last update: 2017-09-23 00:31
  enquiry
detailed
 12.1 inch TFT color screen , big screen could show more information.  Screen could be rotated freely, suitable to operate in any angle and height  With heater device to prevent water into ventilator  Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or several waveform according to our operation.  Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.  Curve pause function, could watch details.  Flow, pressure two trigger function, could effect at a same time.  Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;  100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.  High, medium, low- grade alarm function;  Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm parameter.  Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the regulated value, turn into expiratory, ensure patient safety.  Volume security function, keep the minimum tidal volume in pressure mode.  Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal volume and minute ventilator.  VGA connector could output the screen signal to other screen Specification Operating Modes Volume Control Ventilation (VCV) Assisted/Controlled Pressure Control Ventilation (PCV), Assisted/Controlled Pressure Support Ventilation (PSV), SIMV(VCV)+PSV SIMV(PCV)+PSV Mandatory Minute Ventilation (MMV) Continuous Positive Airway Pressure(CPAP) Backup Apnea Ventilation Parameter Application scope: Pediatric and adult Driven mode: Pneumatically driven and electronically controlled Display:12.1 TFT screen Working mode: Pressure and volume Ventilation wave type: Squire wave, deceleration wave FiO2: 21% to 100% PEEP/CPAP: 0 to 40 cmH2O Inspiratory Sensitivity: Flow triggered: 0.5 to 20 L/min, OFF Pressure triggered: -1 to -20 cmH2O, OFF Tidal Volume: 20 to 2000 mL Breath frequency: 1 to 100 bpm I:E Ratio: 5.0 : 1 to 1 : 5.0 Inspiratory plateau: 0 to 50% Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave SIGH: 1.0 to 2.0 Breath frequency(SIMV): 2 to 40bpm Inspiratory time (SIMV): 0.1 to 12 S Pressure Support Ventilation (PSV): 0 to 40 cmH2O Expiratory Sensitivity for PSV : 10% to 75% of the initial flow Maximum Inspiratory time (PSV): 1.0 to 8.0 S Pressure Control Ventilation(PCV): 0 to 40 cmH2O Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL Backup Rate (PSV): 2 to 40 bpm Object Tidal Volume(MMV): 20 to 2000 mL Ventilation volume(MMV): 0.5 to 40.0 L/min Nebulizer time: 30 minutes
inquiry list